B Secondary Power Distribution  
MCCB  
005-010  
CDM3S Moulded circuit breaker ------------------------------------------------------005  
CDM3E Electronic moulded case circuit breaker----------------------------------007  
CDM3LS Earth Leakage Moulded Circuit breaker --------------------------------008  
CDM3T Moulded case circuit breaker------------------------------------------------010  
CDM3LT Moulded case circuit breaker-----------------------------------------------010  
ATS  
011-013  
CDQ0s PC-grade automatic transfer switch---------------------------------------- 011  
CDQ1s PC-grade automatic transfer switch---------------------------------------- 011  
CDQ1F PC-grade automatic transfer switch---------------------------------------- 011  
CDQ3H CB Product Model--------------------------------------------------------------012  
CDQ3EH CB Product Model -----------------------------------------------------------013  
CDQ6i Product Model -------------------------------------------------------------------013  
Disconnector  
014-017  
HGL disconnector -------------------------------------------------------------------------014  
HGLZ disconnector -----------------------------------------------------------------------014  
HH15 disconnector fuse set-------------------------------------------------------------015  
HR5 fuse type disconnector ------------------------------------------------------------016  
HR17 fuse type disconnector ----------------------------------------------------------016  
CDHR16 bar shape fuse disconnector ----------------------------------------------017  
CDGNE-50 ----------------------------------------------------------------------------------017  
CDH8 series DC disconnector ---------------------------------------------------------017  
Fuse  
018-022  
RT16(NT) knife shape contact fuse --------------------------------------------------018  
RT16-3B (NT3B) fuse link --------------------------------------------------------------018  
RT16 fuse base ----------------------------------------------------------------------------018  
RS38 Model Section ---------------------------------------------------------------------020  
CDPV1-20 fuse used for Solar PV system protection----------------------------021  
CDPV2-32 (L) fuse used for Solar PV system protection -----------------------021  
Straight Pipe --------------------------------------------------------------------------------022  
Selection Guide  
CDM3S Moulded Circuit Breaker  
005  
Selection Guide  
Accessory Selection  
Electrical Accessories  
CDM3S Frame current  
Installation position Accessory name  
Voltage type (shunt/undervoltage) Type  
63/100/125  
125b  
Left  
Shunt (MX)  
AC230  
Wire lead 0.5m (default)  
Wire lead 1m  
Right  
Alarm (SD)  
AC400V  
160/250  
400/630  
630b  
Undervoltage (MN)  
Auxiliary (OF) Dual aux.  
(Dual OF)  
DC24V  
Wire lead 1.5m  
Wire lead 2m  
DC110V/AC110V  
DC220V  
CDM3s  
Terminal  
800  
Aux. alarm (OFSD)  
1250  
1600  
Notes: Except for undervoltage, the electrical accessory type adopts wire lead 0.5m. Optional 1m. 1.5m, and 2m: default undervoltage type is terminal  
Shunt voltage types:  
Undervoltage voltage types: AC400V, AC230V (with left installation supported only)  
Operation Accessories  
CDM3S  
Frame current  
Accessory name  
Voltage type  
63/100/125  
125b  
Motor mechanism  
AC230V/DC220V  
AC400V  
Square manual mechanism  
Round manual mechanism  
Extended square manual mechanism  
Extended round manual mechanism  
Extended round manual mechanism  
Special manual mechanism for machine  
tool  
160/250  
400/630  
630b  
DC24V  
DC110V/AC110V  
800  
1250  
1600  
Other Accessories  
CDM3S  
Frame current  
Accessory name  
Number of poles  
63/100/125*  
125b  
Extended terminal  
Interphase barriers  
Lug  
3P  
4P  
160/250  
400/630  
630b  
Pad Lock  
Terminal cover  
800  
1250  
1600  
Note: For 125C/S breaking type, no Pad lock, and this accessory is in development. Please contact sales for further support.  
006  
Selection Guide  
CDM3E Electronic Moulded Case Circuit Breaker  
Notes:  
No communication function is available for 1250A and 1600A  
No overload alarm function is available for 1250A and 1600A  
No AC110V, DC110V, and DC220V control voltage for 1250A and 1600A shunt and motor mechanism  
For 800 frame and below internal accessories (except for terminal type supplied for undervoltage) and other products, the length of wire lead  
is 500mm as standard configuration; if other length or terminal type is required, please specify;  
No pull-out type is available for 125AF and 250AF; not plug-in front-panel product is available for 400AF and 630AF;  
The horizontal outlet terminal block is defaulted for plug-in front-panel product;  
Standard configuration of conventional product: phase partition arc plate, and mounting screws  
Three-remote standard configuration (aux. alarm + communication module); four-remote standard configuration (aux. alarm + motor  
mechanism + communication module). The voltage of the communication module is AC230V/400V  
CDM3LS Earth Leakage Moulded Circuit breaker  
007  
Selection Guide  
CDM3LS Earth Leakage Moulded Circuit Breaker  
008  
Selection Guide  
Accessory Selection  
Electrical Accessories  
CDM3LS  
Installation position Accessory name  
Voltage type (shunt/undervoltage)  
Frame current  
Type  
Default: wire lead 0.5m (undervoltage as terminal)  
100: wire lead 1m  
63/100  
125  
Left  
Shunt  
AC230  
Right  
Alarm  
AC400V  
160/250  
400/630  
800  
Undervoltage  
Aux.  
DC24V  
150: wire lead 1.5m  
200: wire lead 2m  
DC110V/AC110V  
DC220V  
Dual aux.  
Aux. alarm  
Terminal  
Notes: Except for undervoltage, the electrical accessory type adopts wire lead 0.5m. Optional 1m, 1.5m, and 2m: default undervoltage type is  
terminal  
Shunt voltage types:  
Undervoltage voltage types: AC400V, AC230V (with left installation supported only)  
Operation Accessories  
CDM3LS  
Frame current  
Accessory name  
Voltage type  
63/100  
125  
Motor mechanism  
AC230V/DC220V  
AC400V  
Square manual mechanism  
Round manual mechanism  
160/250  
400/630  
800  
DC24V  
Extended square manual mechanism DC110V/AC110V  
Extended round manual mechanism  
Extended round manual mechanism  
Special manual mechanism for  
machine tool  
Other Accessories  
CDM3LS  
Frame current  
Accessory name  
Number of poles  
63/100  
125  
Extended terminal  
Phase partition  
Junction pole  
3P  
4P  
160/250  
400/630  
800  
Handle position lock  
Terminal cover  
009  
Selection Guide  
CDM3T Moulded Case Circuit Breaker  
Breaking  
capacity  
Number  
of poles  
Operation  
method  
Installation  
method  
Rated  
current  
Product model Frame current  
CDM3T - 100  
Trip mode  
3
Accessory  
00  
Protection type  
2
/
S
3
Default  
Default  
63A  
16A  
100:100A  
S
L
F
3: 3  
2: Single  
magnetic  
trip  
00: No  
Default: Power Default:  
Default: Fixed  
accessories  
08: Alarm  
10: Shunt  
125:125A  
160:160A  
250:250A  
400:400A  
630:630A  
poles  
distribution  
protection  
2: Motor  
Operation  
via handle  
type front-panel 20A  
25A  
32A  
40A  
50A  
63A  
80A  
...  
20: Aux.  
3: Thermal  
magnetic  
trip  
30:  
protection  
Undervoltage  
40: Shunt + Aux.  
50: Shunt +  
Undervoltage  
60: Two sets  
of aux.  
18: Shunt  
630A  
+ Alarm  
28: Aux. + Alarm  
Notes:  
1. Shunt/aux./alarm contacts have terminal and wire lead types, and the wire lead type is available as standard configuration; only terminal is  
provided for undervoltage; the default length of the wire lead is 500mm  
2. Standard configuration for conventional product: phase partition and mounting screws (no wiring copper bar)  
3. For breaking capacity values, refer to the specimen or the information on the front side of product  
CDM3LT Moulded Case Circuit Breaker  
Product  
model  
Frame  
current  
Breaking  
capacity  
Four-pole  
type  
InstallationRated Ratedresidual  
method current operatingcurrent  
Limit non-  
drive time  
Operation  
method  
Number  
of poles  
Trip mode Accessory  
Protection type  
/
CDM3LT  
-
125  
S
4
3
00  
2
A
Default Default 63A  
03/1/3  
125:125A  
250:250A  
S
4: 4 2: Single 00: No  
Default: Power A: Three  
protective  
Default: Default: 16A  
Operation Fixed type 20A  
30/100/300mA  
Default: Non-delay  
accessory  
poles magnetic  
trip  
distribution  
100/300/500mA Delay 1:  
0.1/0.2/0.3s  
Delay 2: 0.4/0.5/1s  
poles with  
neutral lines via fixed front-panel 25A  
that cannot  
be open  
08: Alarm  
protection  
2: Motor  
10: Shunt  
3: Thermal  
magnetic  
trip  
handle  
32A  
40A  
50A  
63A  
...  
20: Aux.  
protection  
and closed  
B: Three  
40: Shunt + Aux.  
60: Two sets  
of aux.  
protective  
poles with  
neutral lines  
that can be  
open and  
closed  
18: Shunt  
+ Alarm  
250A  
28: Aux. + Alarm  
30/100/300mA: 03/1/3  
100/300/500mA: 1/3/5  
Notes:  
1. Shunt/aux./alarm contacts have terminal and wire lead types, and the wire lead type is available as standard configuration; the default length of  
the wire lead is 500mm  
2. Standard configuration for conventional product: phase partition and mounting screws (no wiring copper bar)  
3. Fixed delay product shall be specially ordered;  
4. For breaking capacity values, refer to the specimen or the information on the front side of product  
5. The rated residual operating current is 30/100/300mA; only non-delay type product is provided;  
010  
Selection Guide  
CDQ0s Pc-Grade Automatic Transfer Switch  
Product name  
CDQ0s  
Frame size  
63  
Number of poles  
3
Rated operating current  
/
63A  
63:63AF  
2: 2 poles  
3: 3 poles  
4: 4 poles  
16A  
125:125AF  
250:250AF  
250A  
CDQ1s Pc-Grade Automatic Transfer Switch  
Rated operating current  
016  
Product name  
CDQ1s  
Frame size  
100  
Number of poles  
4
Controller type  
B
Wiring method  
Default  
100:100AF  
160:160AF  
250:250AF  
630:630AF  
16X:1600AF  
32X:3200AF  
016:16A  
2: 2 poles  
3: 3 poles  
4: 4 poles  
Default: Basic type  
Default: Top inlet  
B: Digital display type D: Bottom inlet  
630:630A  
12X:1250A  
32X:3200A  
Note: Only 2-pole products are available for 250AF and below  
CDQ1F Pc-Grade Automatic Transfer Switch  
Number of poles Rated operating current Number of positions  
Product name  
CDQ1F  
Use category  
Frame size  
63  
Controller type  
4P  
16  
A
Default:AC-33B  
(63AF~800AF)  
AC-33iB  
63:63AF  
4P: 4 poles  
3P: 3 poles  
2P: 2 poles  
6:6A  
II: II section  
type  
A: A type controller  
(dial type)  
125:125AF  
250:250AF  
630:630AF  
800:800AF  
1250:1250AF  
1600:1600AF  
10:10A  
16:16A  
20:20A  
……  
III: III section  
type  
B: B type controller  
(digital type)  
(1250AF/1600AF)  
H:AC-33A  
C: C type controller  
(LCD type)  
(63AF/125AF)  
AC-33iA  
1250:1250A  
1600:1600A  
(250AF~800AF)  
011  
Selection Guide  
CDQ3H CB Product Model  
Breaking capacity Rated operating current Number of positions  
Product name  
CDQ3H  
Controller model  
A
Frame size  
100  
Structure form  
Z
F
10  
4
A: A type  
63: 63AF  
S: 35KA  
F: 50KA  
N: 70KA  
L: 15KA  
M: 15KA  
10: 10A  
...  
3: 3 poles  
4: 4 poles  
Default: Split type  
(Only for B type)  
Z: Integral type  
(Economic type)  
100: 100AF  
B: B type (Standard type / 250: 250AF  
100: 100A  
...  
Basic type)  
400: 400AF  
630: 630AF  
250: 250A  
...  
(Only for B type)  
800: 800AF  
400: 400A  
630: 630A  
800: 800A  
(Only for B type)  
Note: The default length of the wire of the split type controller is 1.6m, and the customizable lengths are 2m, 2.5m, 3m, 3.5m, 4m, 4.5m, and 5m.  
CDQ3H CB Product Model  
Number of positions  
Product name  
CDQ3H  
Controller model  
A
Frame size  
63  
Trip curve  
C
Rated current  
10  
Additional function  
G1)  
4
A: A type  
63: 63AF  
C: C type  
10:10A  
...  
42P: 2P  
3: 3P  
-: Grid - grid  
(Economic type)  
B: B type  
(For power  
distribution)  
D: D type  
G: Grid - generator  
63:63A  
4: 4P  
(Standard type)  
(For motor)  
-: Empty  
1) The generator start function is available only for B type  
012  
Selection Guide  
CDQ3EH CB Product Model  
Product name  
Controller  
model  
Number  
of poles  
Additional  
function  
Frame size  
63  
Trip curve  
C
Rated current  
10  
CD  
Q
3
EH  
B
4
G1)  
CD: Delixi,  
China  
Q:  
3:  
EH: CB  
A: A type  
(Economic  
type)  
63: 63AF  
C: C type  
10:10A  
...  
42P: Two-pole -: Grid - grid  
3: Three-pole G: Grid -  
Automatic  
transfer  
switching  
equipment  
Design grade  
code MCB  
(For industry)  
D: D type  
63:63A  
4: Four-pole  
generator  
Upgraded B: B type  
(For motor)  
type  
(Standard  
type)  
-: Empty  
1) The generator start function is available only for B type  
CDQ3EH CB Product Model  
A type  
B type  
Circuit breaker  
trip curve  
Frame current  
Resistive current  
Number of poles  
10  
...  
63  
C
...  
D
CDQ3EHA63C1042P  
...  
CDQ3EHA63D1042P  
CDQ3EHB63C1042P  
...  
CDQ3EHB63D6342P  
2P1)2)  
3P2)  
4P  
10  
...  
63  
C
...  
D
CDQ3EHA63C103  
...  
CDQ3EHA63D633  
CDQ3EHB63C103  
...  
CDQ3EHB63D633  
63AF  
CDQ3EHA63C104  
...  
CDQ3EHA63D634  
CDQ3EHB63C104  
...  
CDQ3EHB63D634  
10  
...  
63  
C
...  
D
1) 2P is a special product  
2) 2P/3P/4P products have the consistent dimensions  
CDQ6i PC Product Model  
Product Name  
CDQ6i  
Frame Current Controller  
Rated Current (A)  
016  
Poles  
Incoming Method Export Version  
100  
A
2
T
E
016: 16A  
020/025/032/040/050/063/080  
100: 100A  
125: 125A  
140: 140A  
160: 160A  
180: 180A  
200/225  
100: 100AF  
160: 160AF  
250: 250AF  
630: 630AF  
2: 2P  
3: 3P  
4: 4P  
A: Integrated controller  
w/o screen  
250: 250A  
B: Integrated controller  
with LED screen  
T: LINE on top  
315: 315A  
350/400/500  
630: 630A  
700: 700A  
800: 800A  
10X: 1000A  
12X: 1250A  
16X: 1600A  
20X: 2000A  
25X: 2500A  
32X: 3200A  
E: English version  
D: LINE on bottom  
C: Separated controller  
with LCD screen  
16X: 1600AF  
32X: 3200AF  
3: 3P  
4: 4P  
013  
Selection Guide  
HGL Disconnector  
Number  
of poles  
Operation  
method  
Double throw switch  
structure type  
Product name  
HGL  
Derivative model Current spec.  
16  
Aux. contact  
11  
View window  
Z
3
J
K
C
Default: Single 16:16A  
3:3P  
4:4P  
Default: In-  
Default:  
Default: Without Default: Up and  
throw switch  
Z: Double  
cabinet operation without aux.  
J: Out-of-cabinet 11: With one  
view window  
K: With view  
window  
down type  
C: Left and  
right type  
3150:3150A  
throw switch  
i: K series  
operation  
pairs of aux.  
22: With two  
pairs of aux.  
T: Transparent type  
HGLZ Disconnector  
Number of  
poles  
Double throw switch  
structure type  
Product name  
HGL  
Derivative model Current spec.  
Operation method Aux. contact  
View window  
K
Z
16  
3
J
11  
C
Default: Single  
throw switch  
Z: Double  
16:16A  
3:3P  
4:4P  
Default: In-  
Default:  
Default:  
Default: Up and  
cabinet operation without aux.  
J: Out-of-cabinet 11: With one  
Without view down type  
3150:3150A  
window  
C: Left and right type  
throw switch  
i: K series  
operation  
pairs of aux.  
22: With two  
pairs of aux.  
K: With view  
window  
014  
Selection Guide  
HH15 Disconnector Fuse Set  
Product name  
HH15  
Current  
63  
Number of poles  
3
Aux. contact type  
D
Additional instruction  
T
HH15:Single throw  
HH15S:Dual throw  
63:63A  
1250:1250A  
...  
3: 3P  
D: No aux. contact  
L: With one pairs of  
aux. contacts  
T: In-cabinet operation; out-  
of-cabinet operation by default  
W: No handle  
4: 4P, with the Neutral pole  
that can be turned on/off  
3N: 4P, with fixed  
Z: With two Pairs of  
aux. contacts  
Default: With handle  
connecting neutral pole  
J20: Rod extended by 20cm  
Rated operating  
current  
Product name  
HH15  
Derivative model  
Number of poles  
Aux. contact  
Additional instruction  
T
125  
3
D
Contact series structure Default: Single  
125:125A  
...  
3: 3P  
D: No aux. contact  
L: With one pairs  
of aux. contacts  
Z: With two pairs  
of aux. contacts  
Default: Out-of-  
cabinet operation  
T: In-cabinet  
Contact parallel  
structure  
throw switch  
S: Dual throw  
switch  
4: 4P, with the neutral pole  
that can be turned on/off  
3N: 4P, with fixed  
1600:1600A  
operation  
connecting neutral pole  
W: No handle  
J20: Rod extended  
by 20cm  
W: No handle  
015  
Selection Guide  
Product name  
HR5  
Current  
160  
Number of poles  
3
Aux. switch type  
L
160:160A  
400:400A  
...  
3:3P  
L: With fuse signal device (with a  
fuse link with a fuse sticker)  
D: Without fuse signal device (with a  
fuse link with a fuse indicator)  
HR fuse type disconnector  
Fuse link and aux. switch combination type  
YD  
Product name  
HR17  
Current  
160  
Number of poles  
Installation method  
3
32:32A  
250:250A  
...  
3:3P  
YD: With fuse link, without aux. switch No: Common type  
YL: With fuse link and aux. switch M: Bus type  
800:800A  
016  
Selection Guide  
CDHR16 Bar Shape Fuse Disconnector  
Product name  
CDHR16  
Resistive current  
160  
Operation method  
L
Combination type  
DT  
160:160A  
250:250A  
400:400A  
630:630A  
L: Integrated: Three phases  
work simultaneously  
DT: With fuse link  
DZT: With straight contact  
Default: No  
Default: Split type, please  
operating separately  
Product series No.  
CDGNE-50  
Design code  
L
Number of layers Wiring method  
Handle type  
Product No.  
2
1
1
1
L: Common type  
2: 2 layers  
1: Two layers  
1: Standard handle  
2: Padlock handle  
1/2/3 see the  
M: Standard type 3: 3 layers  
connected in series  
2: Two layers connected to  
the same negative pole  
parameters table  
H: High  
4: 4 layers  
6: 6 layers  
8: 8 layers  
breaking type  
CDH8 Series DC Disconnector  
Product name  
CDH8  
Current spec.  
160  
Number of poles  
Additional instruction  
J
03  
160:160A  
The first digit indicates the number of  
poles on the left side of the mechanism  
The second digit indicates the number of  
poles on the right side of the mechanism  
03: 3 poles (all three poles are on  
the right side of the mechanism)  
04: 4 poles (all four poles are on the  
right side of the mechanism)  
"J": Out-of-cabinet operation, with  
in-cabinet operation by default  
630:630A  
12: 3 poles (one pole on the left side  
of the mechanism, two poles on the  
right side of the mechanism)  
22: 4 poles (two poles on the left side  
of the mechanism, two poles on the  
right side of the mechanism)  
017  
Selection Guide  
RT16(NT) Knife Shape Contact Fuse  
■ RT16 Fuse Link  
Product name  
RT16  
Spec.  
00  
Type  
T
Rated current  
2
00: 00 type  
1: 1 type  
2: 2 type  
3: 3 type  
4: 4 type  
T: Fuse link  
2:2A  
40:40A  
315:315A  
4:4A  
50:50A  
355:355A  
400:400A  
500:500A  
630:630A  
800:800A  
1000:1000A  
1250:1250A  
6:6A  
63:63A  
8:8A  
80:80A  
10:10A  
12:12A  
16:16A  
20:20A  
25:25A  
32:32A  
100:100A  
125:125A  
160:160A  
200:200A  
224:224A  
250:250A  
■ RT16-3B (NT3B) Fuse Link  
Product name  
RT16  
Spec.  
3
Code  
Type  
Rated current  
B
T
800  
3: 3 type  
Derivative type  
T: Fuse link  
800:800A  
■ RT16 Fuse Base  
Product name  
RT16  
Spec.  
00  
Type  
Z
00: 00 type (with matched RT16-  
000, RT16-00 fuse link)  
1: 1 type  
Z: Base  
2: 2 type  
3: 3 type  
4: 4 type  
Product name  
RT16  
Spec.  
00  
Code  
B
Type  
Z
00: 00 type (with matched RT16-000, RT16-00 B: Derivative type  
fuse link)  
Z: Base  
018  
Selection Guide  
■ RT16-00/3P, 4P Fuse Base  
Product name  
RT16  
Spec.  
00  
Type  
Z
Number of poles  
3
00: 00 type  
Z: Base  
3:3P  
4:4P  
■ CRT16-00 Fuse Link  
Product name  
CRT16  
Spec.  
00  
Type  
T
Rated current  
4
~
00: 00 type  
T: Fuse link  
4 600A  
■ CRT16-00 Fuser Base  
Product name  
CRT16  
Spec.  
00  
Rated current  
160  
Type  
Z
~
00: 00 type  
160 600A  
Z: Base  
019  
Selection Guide  
RT16A Fuse Link  
Product name  
RT16A  
Spec.  
Type  
T
Rated current  
2
00  
A: Striker  
00: 00 type  
1: 1 type  
2: 2 type  
3: 3 type  
T: Fuse link  
2:2A  
32:32A  
224:224A  
250:250A  
315:315A  
355:355A  
400:400A  
500:500A  
630:630A  
4:4A  
40:40A  
50:50A  
6:6A  
63:63A  
8:8A  
80:80A  
10:10A  
12:12A  
16:16A  
20:20A  
25:25A  
100:100A  
125:125A  
160:160A  
200:200A  
Product name  
RS  
Fuse tube diameter  
Fuse tube type  
Rated voltage  
G
Rated current of fuse link  
M
~
38: 38mm  
51: 51mm  
63: 63mm  
Round pipe bolt mounted G: 500V and above  
H: 1000V and above  
35 800A  
020  
Selection Guide  
CDPV1-20 Fuse Used For Solar PV System Protection  
Product name  
CDPV1  
Spec.  
20  
Type  
T
Rated current  
1
20: 20 type  
T: Fuse link  
1: 1A  
2: 2A  
3: 3A  
4: 4A  
5: 5A  
6: 6A  
8: 8A  
10: 10A  
12: 12A  
15: 15A  
20: 20A  
Product name  
CDPV1  
Spec.  
20  
Indicator  
X
20: 20 type  
X: With indicator  
Default: without indicator  
CDPV2-32 (L) Fuse Used For Solar PV System Protection  
Product name  
CDPV2  
Spec.  
32  
Size  
L
Type  
T
Rated current  
1
32: 32 type  
L: 10×85  
T: Fuse link  
1~32A  
Default: 10×65  
Product name  
CDPV2  
Spec.  
32  
Size of matched fuse link  
L
Type  
G
Resistive current  
32  
32: 32 type  
L: 10×85  
G: Fuse type disconnector  
32A  
Default: 10×65  
021  
Selection Guide  
Straight Pipe  
Product name  
Fuse tube type  
ZT  
1038  
1038:10x38  
1451:14x51  
2258:22x58  
ZT: Copper straight pipe  
Scope of Application  
10 x 38, 14 x 51, 22 x 58 copper straight pipes are used in the AC 50Hz line with rated insulation voltage  
500V and with rated operating current up to 125A as N pole. It can be equipped with a cylindrical hat support  
/ base and fuse type switch disconnector for insulation of power supply by cooperating with the fuse.  
Outline and Installation Dimensions (mm)  
Outline dimensional drawing for 10 x 38, 14 x 51, 22 x 58 copper straight pipes  
Outline and Installation Dimensions of Fuse  
Model  
10x38  
14x51  
22x58  
Name  
D
L
Remarks  
Copper straight pipe  
Copper straight pipe  
Copper straight pipe  
Ø10±0.2  
Ø14±0.2  
Ø22±0.2  
38±0.5  
51±0.5  
58±0.5  
Suitable for supports of RT18-32, RT14-20  
Suitable for supports of RT18-63, RT14-32  
Suitable for supports of RT18-125, RT14-63  
022